man powermust (Administration système) - powermust Driver for Mustek PowerMust series UPS equipment

NAME

powermust Driver for Mustek PowerMust series UPS equipment

NOTE

This man page only documents the hardwarespecific features of the powermust driver. For information about the core driver, see nutupsdrv(8).

SUPPORTED HARDWARE

The powermust driver is known to work with the following UPSes:

Maxxtro UPS 600VA Mustek PowerMust 400VA Plus Mustek PowerMust 600VA Plus Mustek PowerMust 800VA Pro Mustek PowerMust 1000VA Plus Mustek PowerMust 1400VA Plus Mustek PowerMust 2000VA USB OnLite AQUA 50 Soyntec Sekury C 500 Soyntec Sekury C 800 Square One Power QP 1000 Tecnoware Easy Power 1200 Trust UPS 1000 Management PW-4105

It is also known to work with various models from Blazer, Energy Sistem and Fenton Technologies. It may also work with similar models from other manufacturers, but they haven't been tested.

EXTRA ARGUMENTS

This driver does not support any extra settings in the ups.conf(5).

UPS COMMANDS

This driver supports some extra commands (see upscmd(8)):

shutdown.return
Turn off the load and return when power is back
shutdown.stayoff
Turn off the load and remain off
shutdown.stop
Stop a shutdown in progress
load.on
Turn on the load immediately
load.off
Turn off the load immediately
reset.input.minmax
Reset minimum and maximum input voltage status

USER VARIABLES

The behavior of the driver can be controlled by some user definable variables (see upsrw(8)):

ups.delay.shutdown
Interval to wait after shutdown with delay command (seconds)
ups.delay.start
Interval to wait before (re)starting the load (seconds)

BUGS

No known bugs at the moment.

AUTHOR

Carlos Rodrigues <carlos.efr@mail.telepac.pt>

SEE ALSO

The core driver:

Internet resources:

The NUT (Network UPS Tools) home page: http://www.networkupstools.org/