man sms (Administration système) - Driver for Brazilian SMS UPS equipment

NAME

sms - Driver for Brazilian SMS UPS equipment

NOTE

This man page only documents the hardwarespecific features of the sms driver. For information about the core driver, see nutupsdrv(8).

SUPPORTED HARDWARE

This driver has been tested with :

Manager III 650 VA

Manager III 1300 VA

Manager III 650 VA sinusoidal

Manager III 1300 VA sinusoidal

Sinus Single 2000 VA sinusoidal online

Please report another SMS working models, or sendme the driver detection string.

EXTRA ARGUMENTS

This driver does not support any extra settings in the ups.conf(5).

UPSCMD

test.battery.stop Cancel battery test

test.battery.start Run battery test until battery is low

test.failure.start Simulate power failure

shutdown.return Shut down in .3 minutes and restart in .3 minutes

shutdown.stayoff Shut down in .3 minutes and do not return

shutdown.stop Stop a shutdown command

reset.watchdog Shutdown in 5 minutes and restart in 3 minutes. Call this with upscmd in crontab every minute.