man scli (Commandes) - SNMP Command Line Interface

NAME

scli - SNMP Command Line Interface

SYNOPSIS

scli [options] [hostname] [community]

DESCRIPTION

scli provides a simple command line interface on top of the Simple Network Management Protocol (SNMP). It can be used to read data from devices and to configure them with simple commands. It relies on the capabilities of the devices and thus not all commands may work with all devices.

The optional hostname argument is the name or the IP address of the remote host. scli talks to this host's SNMP agent on the default port number 161 using the SNMP over UDP transport mapping.

The optional community argument is the community string used to communicate with the remote SNMP agent. The default string is public. Please check the configuration of the SNMP agent to get a clue about the community string to use, if the default community string does not work.

OPTIONS

scli accepts the following options:

-V, --version
Show version of program.
-c, --command
Process the given commands and exit.
-d seconds, --delay=seconds
Set delay between screen updates in seconds. The default delay between updates is 5 seconds.
-f, --file
Process commands from a file and exit.
-h, --help
Show summary of scli options.
-i, --inet
Execute in inet mode. This option implies -q, -n and -x.
-n, --norc
Do not evaluate ~/.sclirc on startup.
-p number, --port=number
Set the SNMP port number. The default port number is 161.
-q, --quiet
This flag causes scli to supress some informational messages.
-r count, --retries=count
The number of SNMP retransmissions before we give up. The default number of retries is 5.
-s, --dry-run
Parse scli commands but do not actually execute them. This allows to perform syntax checking on scli scripts.
-t msec, --timeout=msec
The initial timeout in milli-seconds before an SNMP request is transmitted. The default initial timeout interval is 200 milli-seconds.
-v version, --snmp=version
The SNMP protocol version to use. Recognized values are 1 (SNMPv1 as defined in RFC 1157), 2c (SNMPv2c as defined in RFC 1901, RFC 1905), or 3 (SNMPv3 as defined in RFC 2571-2574). Without this option, scli will probe for an appropriate SNMP version.
-x, --xml
Generate XML output instead of the default output which is optimized for humans and more difficult to parse by programs.

COMMAND OVERVIEW

scli is a simple command interpreter. scli commands are organized in a hierarchy. This section only describes the top-level commands. Invoke the help command described below to get a complete list of all commands supported by scli.

open
Establish an association to a remote SNMP agent.
close
Close the association to a remote SNMP agent.
exit
Exit the scli command interpreter.
help
Display help information about the scli command interpreter including a full list of the scli command hierarchy.
history
Show the history of the last scli commands.
create
Create new object instances on the remote SNMP agent. This command has many sub-commands which are used to instantiate very different things.
delete
Delete object instances from the remote SNMP agent. This command has many sub-commands which are used to delete very different things.
set
Modify object instances on the remote SNMP agent by assigning new values. This command has many sub-commands which are used to set very different things.
show
Show information provided by the remote SNMP agent. This command has many sub-commands focusing on various aspects of the system.
monitor
Monitor information provided by the remote SNMP agent. This command has many sub-commands focusing on various aspects of the system. scli monitors provide a live display of network and device activities. Information is shown in a compact human readable format and updated in regular intervals. The initial update interval length is determined by the delay command line option.
dump
Dump scli command sequences to restore the configuration of the remote SNMP agent.

scli supports recursive command evaluation. When a command is entered which is not a leaf of the command tree, then the interpreter will recursively invoke all commands in the subtree identified by the entered command. In particular, entering show will cause scli to retrieve and display all information accessible from the remote SNMP agent.

3COM MODE

The 3com scli mode allows to manipulate virtual lans (vlans) on 3com bridges. It is based on the PRODUCTMIB which is implemented at least on 3Com SuperStack II switches.

create 3com bridge vlan <vlanid> <name>
delete 3com bridge vlan <regexp>
set 3com bridge vlan name <vlanid> <name>
set 3com bridge vlan ports <regexp> <ports>
show 3com bridge vlan info [<regexp>]
dump 3com bridge vlan

The create 3com bridge vlan command is used to create a new virtual LAN with the given <vlanid> and <name>.

The delete 3com bridge vlan command deletes all selected virtual LANs. The regular expression <regexp> is matched against the virtual LAN names to select the vlans that should be deleted.

The set 3com bridge vlan name command changes the name of a virtual LAN.

The set 3com bridge vlan ports command allows to assign ports to port-based virtual LANs. The regular expression <regexp> is matched against the virtual LAN names to select the vlans that should be modified. The <ports> argument contains a comma separated list of port numbers or port number ranges, e.g. 1,5,7-8.

The show 3com bridge vlan info command shows summary information about all selected virtual LANs. The optional regular expression <regexp> is matched against the virtual LAN names to select the virtual LANs of interest. The command generates a table with the following columns:

VLAN virtual LAN number STATUS status of the virutal LAN (see below) NAME name of the virutal LAN INTERFCE virtual LAN interface number PORTS ports assigned to the virtual LAN

The status is encoded in two characters. The first character indicates the status of the row (A=active, S=not in service, R=not ready). The second character indicates virutal LAN type (P=port, I=IP-subnet, O=protocol, S=src address, D=dst address).

The dump 3com bridge vlan command generates a sequence of scli commands which can be used to restore the virtual LAN configuration.

ATM MODE

The atm scli mode is based on the ATM-MIB as published in RFC 2515. This mode is intended to display and configure ATM parameters.

show atm interface info <regexp>
show atm interface details <regexp>

The show atm interface info command displays summary information for all selected ATM interfaces. The optional regular expression <regexp> is matched against the interface descriptions to select the interfaces of interest. The command generates a table with the following columns:

INTERFACE network interface number DESCRIPTION description of the network interface

The show atm interface details command describes the selected ATM interfaces in more detail. The optional regular expression <regexp> is matched against the interface descriptions to select the interfaces of interest.

BRIDGE MODE

The scli bridge mode is based on the BRIDGE-MIB as published in RFC 1493. It provides commands to browse information specific to LAN bridges (also known as layer two switches).

show bridge info
show bridge ports
show bridge stp ports
show bridge forwarding
show bridge filter
show bridge stats
monitor bridge stats

The show bridge info command displays summary information about a bridge, such as the number of ports and the supported bridging functions and associated parameters.

The show bridge ports command displays information about the bridge ports.

The show bridge stp ports command displays information about the bridge ports which participate in the spanning tree protocol. The command generates a table with the following columns:

PORT port number PRIO spanning tree priority of the port STATE spanning tree status of the port P-COST path costs for this port D-ROOT designated root port D-COST designated costs D-BRIDGE designated bridge D-PORT designated port

The status is encoded in two characters. The first character indicates whether STP on the port is enabled (E) or disabled (D). The second character indicates the current status (D=disabled, B=blocking, I=listening, L=learning, F=forwarding, X=broken).

The show bridge forwarding command displays the forwarding data base used by transparent bridges. The command generates a table with the following columns:

PORT port number STATUS status of the forwarding entry ADDRESS address associated with the port NAME name of the address (where known) VENDOR vendor info derived from the address

The show bridge filter command shows filtering information.

The show bridge stats command displays per port statistics for transparent bridges. The command generates a table with the following columns:

PORT port number I-FPS input frames per second O-FPS output frames per second D-FPS discarded frames per second DESCRIPTION description of the port

The monitor bridge stats command shows the same information as the show bridge stats command. Theinformation is updated periodically.

CISCO MODE

The cisco scli mode is used to display and configure cisco parameters.

show cisco ip accounting info
show cisco ip accounting current
show cisco ip accounting snapshot
monitor cisco ip accounting current
monitor cisco ip accounting snapshot

cisco IP accounting info

cisco IP current accounting data

cisco IP snapshot accounting data

cisco IP current accounting data

cisco IP snapshot accounting data

DISMAN MODE

The disman scli mode is based on the DISMAN-SCRIPT-MIB as published in RFC 3165 and the DISMAN-SCHEDULE-MIB as published in RFC 3231. It allows to browse and configure distributed managers.

create disman script <owner> <name> <description>
create disman run <owner> <name> <args>
show disman languages
show disman script info
show disman script details
show disman launch info
show disman launch details
show disman run info
show disman run details
show disman scheduler info
show disman scheduler details
monitor disman run

languages supported by the distributed manager

script summary information

scripts installed at the distributed manager

launch summary information

launch buttons installed on the distributed manager

summary information about running scripts

running scripts on the distributed manager

scheduler information

schedules on the distributed manager

monitor running scripts

ENTITY MODE

The entity scli mode is based on the ENTITY-MIB as published in RFC 2737. It provides commands to browse the physical entities or physical components that make up a managed system.

show entity info
show entity details
show entity containment

The show entity info command displays summary information about the physical entities that compose the system. The command generates a table with the following columns:

ENTITY entity number CLASS class of the entity (see below) NAME name of the entity DESCRIPTION description of the entity

The show entity details command describes the physical entities in more detail.

The show entity containment command displays the physical entity containment hierarchy.

ETHERNET MODE

The ethernet scli mode is based on the EtherLike-MIB as published in RFC 2665 and the MAU-MIB as published in RFC 2668.

show ethernet mau
show ethernet stats
monitor ethernet stats

The show ethernet mau command displays information about the medium attachment units (MAUs) for each ethernet port. The command generates a table which has the following columns:

INTERFACE network interface number MAU medium attachment unit number per interface STATUS status of the medium attachment unit MEDIA media availability JABBER jabber state of the medium attachment unit AUTONEG autonegation capabilities TYPE type of the medium attachment unit

The show ethernet stats command displays ethernet specific statistics for each ethernet interface. The command outputs a table which has the following columns:

INTERFACE network interface number ALIGN alignement errors per second FCS frame check sequence errors per second RCV MAC receive errors per second LONG frames exceeding maximum frame size per second DEFER deferred transmission per second SCOL single collisions per second MCOLR multiple collisions per second XCOL excessive collisions per second LCOL late collisions per second XMIT MAC transmit errors per second CARR carrier sense errors per second

The monitor ethernet stats command shows the same information as the show ethernet stats command. The information is updated periodically.

INTERFACE MODE

The scli interface mode is based on the IF-MIB as published in RFC 2863. It provides commands to browse, monitor and configure arbitrary network interfaces.

create interface stack <lower-regexp> <higher-regexp>
delete interface stack <lower-regexp> <higher-regexp>
set interface status <regexp> <status>
set interface alias <regexp> <string>
set interface notifications <regexp> <value>
set interface promiscuous <regexp> <bool>
show interface info [<regexp>]
show interface details [<regexp>]
show interface stack [<regexp>]
show interface stats [<regexp>]
monitor interface stats [<regexp>]
alert interface status <regexp> [<regexp>]
dump interface

The set interface status command modifies the administrative status of all selected interfaces. The regular expression <regexp> is matched against the interface descriptions to select the interfaces of interest. The <value> parameter must be one of the strings "up", "down", or "testing".

The set interface alias command assigns the alias name <string> to the selected interfaces. The alias name provies a non-volatile handle which can be used by management applications to better identify interfaces. The regular expression <regexp> is matched against the interface descriptions to select the interfaces.

The set interface notifications command controls whether the selected interfaces generate linkUp and linkDown notifications. The regular expression <regexp> is matched against the interface descriptions to select the interfaces. The <value> parameter must be one of the strings "enabled" or "disabled".

The set interface promiscuous command controls whether the selected interfaces operate in promiscuous mode or not. The regular expression <regexp> is matched against the interface descriptions to select the interfaces. The <bool> parameter must be one of the strings "true" or "false".

The show interface info command displays summary information for all selected interfaces. The optional regular expression <regexp> is matched against the interface descriptions to select the interfaces of interest. The command generates a table with the following columns:

INTERFACE network interface number STATUS interface status (see below) MTU maximum transfer unit TYPE type of the network interface SPEED speed in bits per second NAME name of the network interface DESCRIPTION description of the network interface

The status is encoded in four characters. The first character indicates the administrative status (U=up, D=down, T=testing). The second character indicates the operational status (U=up, D=down, T=testing, ?=unknown, O=dormant, N=not-present, L=lower-layer-down). The third character indicates whether a connector is present (C=connector, N=none) and the fourth character indicates whether the interface is in promiscuous mode (P=promiscuous, N=normal).

The show interface details command describes the selected interfaces in more detail. The optional regular expression <regexp> is matched against the interface descriptions to select the interfaces of interest.

The show interface stack command shows the stacking order of the interfaces. The command generates a table with the following columns:

INTERFACE network interface number STACK indication of the stacking order TYPE type of the network interface DESCRIPTION description of the network interface

The show interface stats command displays network interface statistics for all selected interfaces. The optional regular expression <regexp> is matched against the interface description to select the interfaces. The command outputs a table which has the following columns:

INTERFACE network interface number STATUS interface status (see above) I-BPS input bytes per second O-BPS output bytes per second I-PPS input packets per second O-PPS output packets per second I-ERR input errors per second O-ERR output errors per second DESCRIPTION description of the network interface

The monitor interface stats command shows the same information as the show interface stats command. The information is updated periodically.

The alarm interface status command generates alerts for interfaces that are in given status.

The dump interface command generates a sequence of scli commands which can be used to restore the interface configuration.

IP MODE

The ip scli mode is based on the IP-MIB as published in RFC 2011, the IP-FORWARD-MIB as published in RFC 2096, the IP-TUNNEL-MIB as published in RFC 2667 and the RFC1213-MIB as published in RFC 1213. It provides commands to browse, monitor and configure IP protocol engines.

set ip forwarding <value>
set ip ttl <number>
show ip info
show ip forwarding
show ip addresses
show ip tunnel
show ip mapping
dump ip

The set ip forwarding command controls whether the IP protocol engine forwards IP datagrams or not. The <value> parameter must be one of the strings "enabled" or "disabled".

The set ip ttl command can be used to change the default time to live (TTL) value used by the IP protocol engine. The <number> parameter must be a number between 1 and 255 inclusive.

The show ip info command displays parameters of the IP protocol engine, such as the default TTL or whether the node is forwarding IP packets.

The show ip forwarding command displays the IP forwarding data base. The command generates a table with the following columns:

DESTINATION destination address and prefix NEXT-HOP next hop towards the destination TOS type of service selector TYPE type (direct/indirect) of the entry PROTO protocol which created the entry INTERFACE interface used for forwarding

The show ip addresses command displays the IP addresses assigned to network interfaces. The command generates a table with the following columns:

INTERFACE network interface number ADDRESS IP address PREFIX IP address prefix length NAME name of the IP address

The show ip tunnel command displays information about existing IP tunnels.

The show ip mapping command displays the mapping of IP address to lower layer address (e.g., IEEE 802 addresses). The command generates a table with the following columns:

INTERFACE network interface number STATUS status of the mapping entry ADDRESS IP address ADDRESS lower layer address

The dump ip command generates a sequence of scli commands which can be used to restore the IP configuration.

ISDN MODE

The scli isdn mode is based on the ISDN-MIB as published in RFC 2127.

show isdn bri [<regexp>]
show isdn bearer
show isdn endpoints

The show isdn bri command shows information about the ISDN basic rate interfaces. The command outputs a table which has the following columns:

INTERFACE network interface number TYPE type of the ISDN interface TOPOLOGY line topology MODE interface mode (te/nt) SIGNALING signaling mode (active/inactive) DESCRIPTION description of the network interface

The show isdn bearer command shows information about the ISDN B (bearer) channels.

The show isdn endpoints command shows information about the ISDN endpoints.

NETSNMP MODE

The netsnmp scli mode is used to display and configure netsnmp specific parameters. It is based on the UCD-SNMP-MIB.

set netsnmp debugging <value>
set netsnmp restart
show netsnmp info
show netsnmp load
show netsnmp exec
show netsnmp proc
dump netsnmp

The set netsnmp debugging command controls whether the agent generates debug messages or not. The <value> parameter must be one of the strings "enabled" or "disabled".

The set netsnmp restart command restarts the agent.

The show netsnmp info command shows general information about the netsnmp/ucdsnmp agent such as the version number and the software configuration.

The show netsnmp load command shows the load indices of the system. This is usually the length of the queue in front of the processor(s) averaged over some time interval.

The show netsnmp exec command shows information about pre-configured commands that can be invoked.

The show netsnmp proc command shows information about which processes netsnmp watches.

The dump netsnmp command generates a sequence of scli commands which can be used to restore the netsnmp specific configuration.

NORTEL MODE

The nortel scli mode allows to manipulate virtual LANs (vlans) on nortel bridges. It is based on the RAPID-CITY MIB which is implemented at least on the baystack bridges.

create nortel bridge vlan <vlanid> <name>
delete nortel bridge vlan <regexp>
set nortel bridge vlan name <vlanid> <name>
set nortel bridge vlan ports <regexp> <ports>
set nortel bridge vlan default <string> <ports>
show nortel bridge vlan info [<regexp>]
show nortel bridge vlan details [<regexp>]
show nortel bridge vlan ports
dump nortel bridge vlan

The create nortel bridge vlan command is used to create a new virtual LAN with the given <vlanid> and <name>.

The delete nortel bridge vlan command deletes all selected virtual LANs. The regular expression <regexp> is matched against the virtual LAN names to select the vlans that should be deleted.

The set nortel bridge vlan name command changes the name of a virtual LAN.

The set nortel bridge vlan ports command allows to assign ports to port-based vlans. The regular expression <regexp> is matched against the vlan names to select the vlans that should be modified. The <ports> argument contains a comma separated list of port numbers or port number ranges, e.g. 1,5,7-8.

The set nortel bridge vlan default command allows to assign ports to a default vlan. The <string> argument is matched against the vlan names to select the vlan. The <ports> argument contains a comma separated list of port numbers or port number ranges, e.g. 1,5,7-8.

The show nortel bridge vlan info command shows summary information about all selected virtual LANs. The optional regular expression <regexp> is matched against the virtual LAN names to select the virtual LANs of interest. The command generates a table with the following columns:

VLAN number of the virtual LAN STATUS status of the virtual LAN (see below) NAME name of the virtual LAN PORTS ports assigned to the virtual LAN

The status is encoded in four characters. The first character indicates the status of the row (A=active, S=not in service, R=not ready). The second character indicates virtual LAN type (P=port, I=IP-subnet, O=protocol, S=src address, D=dst address). The third character indicates the priority of the virtual LAN (H=high, N=normal) and the fourth character indicates whether routing is enabled (R=routing, N=no routing).

The show nortel bridge vlan details command describes the selected vlans in more detail. The optional regular expression <regexp> is matched against the vlan names to select the vlans of interest.

The show nortel bridge vlan ports command shows information for each vlan port. The command generates a table with the following columns:

PORT port number FLAGS port vlan flags (see below) DEFAULT default vlan number VLANS vlan numbers the port is member of

The flags are encoded in four characters. The first character indicates the port type (A=access, T=trunk). The second character indicates whether the port tags frames (T=tagging, N=none). The third character indicates whether the port discards tagged frames (D=discard, N=none) and the fourth character indicates whether the port discards untagged frames (D=discard, N=none).

The dump nortel bridge vlan command generates a sequence of scli commands which can be used to restore the virtual LAN configuration.

OSPF MODE

The scli ospf mode is used to display and configure OSPF parameters.

show ospf area
show ospf info
show ospf interface

show OSPF areas

general OSPF information

show OSPF interfaces

PRINTER MODE

The scli printer mode is based on the Printer-MIB as published in RFC 1759 and some updates currently being worked on in the IETF Printer MIB working group.

set printer operator <string>
show printer info
show printer covers
show printer inputs
show printer outputs
show printer markers
show printer supplies
show printer interpreter
show printer channels
show printer console display
show printer console lights
show printer alerts
monitor printer console display
monitor printer console lights
monitor printer alerts

The set printer operator command configures the name of the person responsible for operating a printer. As a convention, the phone number, fax number or email address should be indicated by the tel:, fax: and mailto: URL schemes.

The show printer info command shows general information about the printer including global status information.

The show printer covers command shows information about the covers of a printer.

The show printer inputs command shows information about the input sub-units of a printer which provide media for input to the printing process.

The show printer output command shows information about the output sub-units of a printer capable of receiving media delivered from the printing process.

The show printer markers command shows information about the marker sub-units of a printer which produce marks on the print media.

The show printer supplies command shows information about the supplies which are consumed and the waste produced by the markers of a printer.

The show printer interpreter command shows information about the page description language and control language interpreters supported by the printer.

The show printer channels command shows information about the channels which can be used to submit data to the printer.

The show printer console display command shows the current contents of the display attached to the printer. The command generates a table with the following columns:

PRINTER logical printer number LINE display line number TEXT contents of the display line

The show printer console lights command shows the current status of the lights attached to the printer. The command generates a table with the following columns:

PRINTER logical printer number LIGHT number identifying the light/led DESCRIPTION description of the light/led STATUS current status (on, off, blink) COLOR current color of the light

The show printer alerts command displays the list of active printer alerts including the alert code, the alert severity, the alert description, the alert time, the alert location and the personel required to handle the alert.

The monitor printer console display command shows the same information as the show printer console display command. The information is updated periodically.

The monitor printer console lights command shows the same information as the show printer console lights command. The information is updated periodically.

The monitor printer alerts command shows the same information as the show printer alerts command. The information is updated periodically. RS232 MODE

The rs232 scli mode is based on the RS-232-MIB as published in RFC 1659.

show rs232 details

SCLI MODE

The scli mode provides commands that can be used to display and manipulate the internal state of the scli interpreter.

open <nodename> [<community>]
close
create scli plugin <module>
delete scli plugin <module>
exit
help
history
create scli alias <name> <value>
delete scli alias <regexp>
create scli interp <name>
delete scli interp <regexp>
set scli regex [<regexp>]
set scli debugging [<regexp>]
set scli pager <pager>
set scli format <fmt>
set scli mode <mode>
show scli info
show scli command info [<regex]
show scli command details [<regex]
show scli command tree
show scli aliases
show scli interps
show scli modes [<regex>]
show scli schema [<regex>]
show scli alarm info

The open command establishes an association to a remote SNMP agent. The <nodename> argument is the DNS name or the IP address of the remote node. Scli will try to talk to the SNMP agent on this node by using the default port number (usually 161) and the default transport mapping (usually SNMP over UDP). The optional <community> argument is the community string needed to communicate with the remote SNMP agent. The default community string is "public". Opening an association while an association is already established is not considered an error. The existing established association will be closed automatically before an attempt to create a new association is started.

The close command closes an established association to a remote SNMP agent. Invoking the close command when no association is established is not considered an error and will do just nothing.

The create scli plugin command dynamically loads an scli mode into a running scli process. This can be used to dynamically extend scli with modules coming from other sources. Dynamic loadable modules also simplify the development and management of site-specific modules.

The delete scli plugin command removes a previously loaded modules from a running scli process.

The exit command terminates the scli interpreter. An end of file in the standard input stream will also terminate the the scli interpreter.

The help command displays some help information including a list of all top-level scli commands.

The history command displays the scli command history list with line numbers.

The create scli alias command creates the alias <name> for the scli command (fragment) <value>. If the alias <name> already exists, then the new <value> will be assigned to the existing alias.

The delete scli alias command removes previously defined aliases from the scli interpreter. The regular expression <regexp> is matched against all alias names in order to select the aliases that are deleted.

The create scli interp command creates a new internal scli interpreter with the name <name>.

The delete scli interp command deletes previously defined scli interpreters from the main scli interpreter. The regular expression <regexp> is matched against all alias names in order to select the interpreter(s) to be removed.

The set scli regex command controls how scli matches regular expressions. The optional regular expression <regexp> is matched against the regular expression options. A successful match turns a regular expression option on while an unsuccessful match turns a regular expression option off. Invoking the command without the <regexp> argument will turn all regular expression options off. The currently defined regular expression options are "extended" for POSIX extended regular expressions and "case-insensitive" for case insensitive matches.

The set scli debugging command sets the debugging level of the SNMP engine. The optional regular expression <regexp> is matched against the debugging levels. A successful match turns a debugging level on while an unsuccessful match turns a debugging level off. Invoking the command without the <regexp> argument will turn all debugging levels off. The currently defined debugging levels are "session" for the SNMP session layer, "request" for the SNMP request handling layer, "transport" for the SNMP transport layer, "packet" for the SNMP packet layer, and "asn1" for the ASN.1 coding layer.

The set scli pager command defines the shell command which is used as a pager if the output produced by an scli command does not fit on a single screen. The output is passed to the <pager> shell command via its standard input stream.

The set scli format command defines the output format used by subsequent scli commands. The currently supported formats are "scli" and "xml". The "scli" format is the default output format and described in this documentation. The "xml" output format is experimental and therefore not described here.

The set scli mode command defines the scli mode used by subsequent scli commands. Setting the mode to "protocol" will force scli to work in protocol mode. Setting the mode to "normal" causes scli to work in normal mode where certain status messages are suppressed.

The show scli info command displays the current status of the scli interpreter.

The show scli command info command displays summary information about scli commands. The optional regular expression <regexp> is matched against the command names to select the scli commands.

The show scli command details command displays detailed information about scli commands. The optional regular expression <regexp> is matched against the command names to select the scli commands.

The show scli command tree command displays the scli command tree. The full command syntax is displayed for each leaf node.

The show scli aliases command lists all scli command aliases. The first column in the generated table lists the aliase names while the second column shows the alias values.

The show scli interps command lists all scli interpreters.

The show scli modes command shows information about the scli modes. An scli mode is a logical grouping of related commands (e.g., all commands that deal with printers). The optional regular expression <regex> can be use to select a subset of the available scli modes.

The show scli schema command produces xml schema definitions for the selected scli modes. An scli mode is a logical grouping of related commands (e.g., all commands that deal with printers). The optional regular expression <regex> can be use to select a subset of the available scli modes.

The show scli alarm info command displays summary information about all known alarms.

SNMP MODE

The snmp scli mode is based on the SNMPv2-MIB as published in RFC 1907, the SNMP-FRAMEWORK-MIB as published in RFC 2571, the SNMP-USER-BASED-SM-MIB as published in RFC 2574, the SNMP-VIEW-BASED-ACM-MIB as published in RFC 2575, the SNMP-TARGET-MIB as published in RFC 2573, and the SNMP-NOTIFICATION-MIB as published in RFC 2573.

create snmp vacm member <name> <group> [<model>]
delete snmp vacm member <regex-name> <regex-group> [<model>]
create snmp usm user <name> <template>
set snmp authentication traps <status>
show snmp engine
show snmp resources
show snmp vacm member
show snmp vacm access
show snmp vacm views
show snmp usm users
show snmp target addresses
show snmp target parameters
show snmp notification targets
dump snmp

The create snmp vacm member commands can be used to assign new members (security names) to vacm groups. New groups are created if they do not exist.

The delete snmp vacm member commands can be used to delete members (security names) from vacm groups. Groups are deleted if the last member is deleted.

The create snmp usm user commands can be used to create a new user by cloning an existing template.

The set snmp authentication traps command controls whether the SNMP engine generates authentication failure notifications. The <value> parameter must be one of the strings "enabled" or "disabled".

The show snmp engine command displays information about the SNMP protocol engine such as the number of boots, the current time relative to the last boot and the maximum message size.

The show snmp resources command displays information about the MIB resources supported by the SNMP agent.

The show snmp vacm member command displays the mapping of security names to group names. The command generates a table with the following columns:

ROW row storage type and status MOD security model NAME member name (security name) GROUP name of the vacm group

The show snmp vacm access command display the access control rules for the security groups. The command generates a table with the following columns:

ROW row storage type and status GROUP security group name MOD security model LVL security level (--, a-, ap) CTX context name MATCH match (exact or prefix) READ view name for read access WRITE view name for write access NOTIFY view name for notification

The show snmp vacm views command displays MIB view definitions. The command generates a table with the following columns:

ROW row storage type and status VIEW view name TYPE access to the view subtree (incl/excl) PREFIX object identifier wildcard prefix

The show snmp usm users command displays the configured users. The command generates a table with the following columns:

ROW row storage type and status USER USM user name NAME security name of the USM user AUTH authentication protocol PRIV privacy protocol

The show snmp target addresses command displays information about the configured SNMP target addresses. The command generates a table with the following columns:

ROW row storage type and status TARGET target name DOMAIN transport domain ADDRESS transport address TMOUT timeout value in ms RETRY number of retries PARAMS associated parameters TAGS tag list

The show snmp target parameters command displays information about the configured SNMP target parameters. The command generates a table with the following columns:

ROW row storage type and status PARAMS parameter name NAME security name

The show snmp notification targets command displays information about the configured SNMP notification targets. The command generates a table with the following columns:

ROW row storage type and status NAME notification target name TYPE notification type TAG tag reference to targets

The dump snmp command generates a sequence of scli commands which can be used to restore the engine configuration.

SONET MODE

The sonet scli mode is based on the SONET-MIB as published in RFC 2558. It provides commands to manage Synchronous Optical Network/Synchronous Digital Hierarchy (SONET/SDH) interfaces.

show sonet media [<regexp>]
show sonet section stats [<regexp>]
show sonet section history [<regexp>]
monitor sonet section stats [<regexp>]

The show sonet media command displays information about the configuration of SONET/SDH interfaces. The command outputs a table which has the following columns:

INTERFACE network interface number SIGNAL type of the signal (SONET/SDH) CODING line coding (B3ZS, CMI, NRZ, RZ) LINE optical or electrical line type DESCRIPTION description of the network interface

The show sonet section stats command displays statistics about SONET/SDH section errors. The command outputs a table which has the following columns:

INTERFACE network interface number INTERVAL measurement interval ES errored seconds SES severely errored seconds SEFS severely errored framing seconds CV coding violations LOSS flags indicating loss of signal/frame DESCRIPTION description of the network interface

The show sonet section history command displays 15 minute history statistics about SONET/SDH section errors. The command outputs a table which has the following columns:

INTERFACE network interface number INTERVAL measurement interval start offset ES errored seconds SES severely errored seconds SEFS severely errored framing seconds CV coding violations DESCRIPTION description of the network interface

The monitor sonet section stats command shows the same information as the show sonet section stats command. The information is updated periodically.

SYSTEM MODE

The system scli mode is primarily based on the SNMPv2-MIB as published in RFC 1907 and the HOST-RESOURCES-MIB as publisched in RFC 2790. It can be used to browse and configure system parameters and characteristics.

set system contact <string>
set system name <string>
set system location <string>
show system info
show system devices
show system storage
show system mounts
show system processes [<regexp>]
monitor system storage
monitor system processes [<regexp>]
dump system

The set system contact command configures the system contact information. The <string> argument should include information on how to contact a person who is responsible for this system.

The set system name command configures the name of the system. By convention, this is the fully-qualified domain name.

The set system location command configures the physical location of the system.

The show system info command shows general information about the system.

The show system devices command shows a list of system devices. The command generates a table with the following columns:

INDEX device number STATUS current status of the device DESCRIPTION description of the device

The show system storage command displays information about the logical areas attached in the system. The command generates a table with the following columns:

INDEX logical storage area number DESCRIPTION description of the storage area TYPE logical storage area type SIZE total size of the storage area USED amount of storage in use FREE amount of storage available USE% used storage in percent

The show system mounts command shows the list of filesystems mounted on the system. The command generates a table with the following columns:

INDEX filesystem identification number LOCAL local root path name of the filesystem REMOTE remote server and root path name (if any) TYPE filesytem type (if known) OPTIONS access mode (ro/rw) and boot flag

The show system processes command display information about the processes currently running on the system. The regular expression <regexp> is matched against the command executed by the process to select the processes of interest.The command generates a table with the following columns:

PID process identification number S status of the process (see below) T type of the process (see below) MEMORY memory used by the process TIME CPU time used by the process COMMAND command executed by the process

The process status values are C=running, R=runnable, S=not runnable, and Z=invalid. The process types values are ?=unknown, O=operating system, D=device driver, and A=application.

The monitor system storage command shows the same information as the show system storage command. The information is updated periodically.

The monitor system processes command show the same information as the show system processes command. The information is updated periodically.

The dump system command generates a sequence of scli commands which can be used to restore the system configuration.

TCP MODE

The scli tcp mode is based on the TCP-MIB as published in RFC 2012. It provides commands to browse information specific to the TCP transport protocol.

show tcp info
show tcp listener
show tcp connections
show tcp states
monitor tcp connections
monitor tcp states

The show tcp info command displays parameters of the TCP protocol engine.

The show tcp listener command displays the listening TCP endpoints. The command generates a table with the following columns:

LOCAL local TCP endpoint STATE transmission control block state (listen)

The show tcp connections command displays the connected TCP endpoints including the current state of the connection as seen by the remote SNMP agent. The command generates a table with the following columns:

LOCAL local TCP endpoint REMOTE remote TCP endpoint STATE transmission control block state

The transmission control block state is either closed, synSent, synReceived, established, finWait1, finWait2, closeWait, lastAck, closing, or timeWait.

The show tcp states command displays the distribution of TCP transmission control block states together with a list of known port names in each state. The command generates a table with the following columns:

COUNT number of transmission control blocks per state STATE transmission control block state PORTS well-known ports associated with the state

The command uses some heuristics to identify the interesting port numbers. First, all local port numbers are considered where the local port number matches one of the listening port numbers. From the remaining connections, all local port numbers are considered with a well known name. From the remaining connections, all remote port numbers are considered with a well known name. All remaining connections are aggregated under the pseudo name - (hyphen). Unspecified port numbers are show using the pseudo name * (star).

The monitor tcp connections command displays the connected TCP endpoints including the current state of the connection as seen by the remote SNMP agent. The information is updated periodically.

The monitor tcp states command displays the distribution of TCP connection states. The information is updated periodically.

UDP MODE

The scli udp mode is based on the UDP-MIB as published in RFC 2013. It provides commands to browse information specific to the UDP transport protocol.

show udp listener
show udp stats

The show udp listener command displays the listening UDP endpoints.

The show udp statistics about datagrams received or sent.

INTERACTIVE MONITOR COMMANDS

Several single-key commands are recognized while scli is running in monitor mode:

space
Update the display.
^L
Redraw the screen.
h or ?
Print a help page.
c
Toggle display of contact summary information.
d
Set the delay in seconds between updates.
m
Toggle display of mode specific summary information.
n
Toggle display of network layer summary information.
q
Quit the monitoring mode.
x
Exit scli immediately.
t
Toggle display of transport layer summary information.
w
Freeze the screen until someone hits a key.

UNITS

scli displays numbers in a compact format. It uses several abbreviations to explain the units of the numbers. Here are some explanations:

bps
Bits per second.
fps
Frames per second.
pps
Packets per second.
sps
Segments per second.

Large numbers are usually displayed with a scaling factor (k=10^3, m=10^6, g=10^9, t=10^12, p=10^15, K=2^10, M=2^20, G=2^30, T=2^40m, P=2^50).

ALIASES

Long command names can be abbreviated by using aliases. The scli interpreter maintains a list of aliases. Every command is first checked whether the first word matches an alias. If the first word matches an alias, then the first word will be replaced by the value of the alias. Alias expansion only happens once.

Aliases are not expanded when the scli interpreter is running in non-interactive mode.

REGULAR EXPRESSIONS

scli generally uses POSIX.2 Extended Regular Expressions. The regular expression matching is case sensitive.

READLINE

scli supports the GNU readline library. The GNU readline library provides command line editing as well as command completion capabilities. Please consult the GNU readline documentation for a detailed description of the readline features.

HISTORY

scli supports the GNU history library. The GNU history library provides a history expansion feature that is similar to the history expansion provided by 'csh'. Please consult the GNU history library documentation for a detailed description of the history features.

PAGER

scli respects the PAGER environment variable when running interactively. If the PAGER environment variable exists and the output generated by an scli command does not fit on the terminal, then the output is written to the standard input of the PAGER.

FILES

~/.scli_history
The history of scli commands.
~/.sclirc
The scli startup file.
~/.inputrc
Individual readline initialization file.

FURTHER INFORMATION

More information can be found on the scli web page which is available at:

<http://www.ibr.cs.tu-bs.de/projects/scli/>

SEE ALSO

AUTHOR

Juergen Schoenwaelder <schoenw@ibr.cs.tu-bs.de>.